CAF700-7500

CAF700 / 7500 Series

CAF700
Specifications:

  • Nominal flow per unit: 1100 m3/h
  • Maximum operating pressure: 10 bar (150 psi), 16 bar, 25 bar
  • Pressure loses during the cleaning: 0.1 bar (2 psi)
  • Highest working water temperature: 65℃ (149°F)
  • Range of filter fineness: 120-4000 um
  • Water volume self-cleaning needed: 80 l
  • Cleaning way: brushes
  • Self-cleaning time: 10 seconds
  • Self-cleaning control mode: pressure gauge control
  • Electronic control mode: Three-phase, 0.37 kW
  • Type of filter screen: 316l woven mesh, wedge-shaped metal-mesh
CAF700-1 CAF700-2

CAF700/7500 series specifications:

CAF700 table
CAF700/7500 Loss of pressure table
CAF700 loss of pressure
CAF700/7500 installation drawings

CAF700 drawings