Specifications:
- Nominal flow per unit: 1100 m3/h
- Maximum operating pressure: 10 bar (150 psi), 16 bar, 25 bar
- Pressure loses during the cleaning: 0.1 bar (2 psi)
- Highest working water temperature: 65℃ (149°F)
- Range of filter fineness: 120-4000 um
- Water volume self-cleaning needed: 80 l
- Cleaning way: brushes
- Self-cleaning time: 10 seconds
- Self-cleaning control mode: pressure gauge control
- Electronic control mode: Three-phase, 0.37 kW
- Type of filter screen: 316l woven mesh, wedge-shaped metal-mesh
CAF700/7500 series specifications:
CAF700/7500 Loss of pressure table
CAF700/7500 installation drawings